现在的位置: 首页 > 综合 > 正文

Shutdown reboot logoff Windows 98/ME/XP

2013年08月12日 ⁄ 综合 ⁄ 共 7055字 ⁄ 字号 评论关闭
{1.} 

function MyExitWindows(RebootParam: Longword): Boolean; 
var 
  TTokenHd: THandle; 
  TTokenPvg: TTokenPrivileges; 
  cbtpPrevious: DWORD; 
  rTTokenPvg: TTokenPrivileges; 
  pcbtpPreviousRequired: DWORD; 
  tpResult: Boolean; 
const 
  SE_SHUTDOWN_NAME = 'SeShutdownPrivilege'; 
begin 
  if Win32Platform = VER_PLATFORM_WIN32_NT then 
  begin 
    tpResult := OpenProcessToken(GetCurrentProcess(), 
      TOKEN_ADJUST_PRIVILEGES or TOKEN_QUERY, 
      TTokenHd); 
    if tpResult then 
    begin 
      tpResult := LookupPrivilegeValue(nil, 
                                       SE_SHUTDOWN_NAME, 
                                       TTokenPvg.Privileges[0].Luid);
      TTokenPvg.PrivilegeCount := 1; 
      TTokenPvg.Privileges[0].Attributes := SE_PRIVILEGE_ENABLED; 
      cbtpPrevious := SizeOf(rTTokenPvg); 
      pcbtpPreviousRequired := 0; 
      if tpResult then 
        Windows.AdjustTokenPrivileges(TTokenHd,
                                      False, 
                                      TTokenPvg, 
                                      cbtpPrevious, 
                                      rTTokenPvg, 
                                      pcbtpPreviousRequired); 
    end; 
  end; 
  Result := ExitWindowsEx(RebootParam, 0); 
end; 

// Example to shutdown Windows: 

procedure TForm1.Button1Click(Sender: TObject); 
begin 
  MyExitWindows(EWX_POWEROFF or EWX_FORCE); 
end; 

// Example to reboot Windows: 

procedure TForm1.Button1Click(Sender: TObject); 
begin 
  MyExitWindows(EWX_REBOOT or EWX_FORCE); 
end; 

// Parameters for MyExitWindows() 

{************************************************************************} 

{2. Console Shutdown Demo} 

program Shutdown; 
{$APPTYPE CONSOLE} 

uses 
  SysUtils, 
  Windows; 

// Shutdown Program 
// (c) 2000 NeuralAbyss Software 
// www.neuralabyss.com 

var 
  logoff: Boolean = False; 
  reboot: Boolean = False; 
  warn: Boolean = False; 
  downQuick: Boolean = False; 
  cancelShutdown: Boolean = False; 
  powerOff: Boolean = False; 
  timeDelay: Integer = 0; 

function HasParam(Opt: Char): Boolean; 
var 
  x: Integer; 
begin 
  Result := False; 
  for x := 1 to ParamCount do 
    if (ParamStr(x) = '-' + opt) or (ParamStr(x) = '/' + opt) then Result := True; 
end; 

function GetErrorstring: string; 
var 
  lz: Cardinal; 
  err: array[0..512] of Char; 
begin 
  lz := GetLastError; 
  FormatMessage(FORMAT_MESSAGE_FROM_SYSTEM, nil, lz, 0, @err, 512, nil); 
  Result := string(err); 
end; 

procedure DoShutdown; 
var 
  rl, flgs: Cardinal; 
  hToken: Cardinal; 
  tkp: TOKEN_PRIVILEGES; 
begin 
  flgs := 0; 
  if downQuick then flgs := flgs or EWX_FORCE; 
  if not reboot then flgs := flgs or EWX_SHUTDOWN; 
  if reboot then flgs := flgs or EWX_REBOOT; 
  if poweroff and (not reboot) then flgs := flgs or EWX_POWEROFF; 
  if logoff then flgs := (flgs and (not (EWX_REBOOT or EWX_SHUTDOWN or EWX_POWEROFF))) or 
      EWX_LOGOFF; 
  if Win32Platform = VER_PLATFORM_WIN32_NT then 
  begin 
    if not OpenProcessToken(GetCurrentProcess, TOKEN_ADJUST_PRIVILEGES or TOKEN_QUERY, 
      hToken) then 
      Writeln('Cannot open process token. [' + GetErrorstring + ']') 
    else 
    begin 
      if LookupPrivilegeValue(nil, 'SeShutdownPrivilege', tkp.Privileges[0].Luid) then 
      begin 
        tkp.Privileges[0].Attributes := SE_PRIVILEGE_ENABLED; 
        tkp.PrivilegeCount           := 1; 
        AdjustTokenPrivileges(hToken, False, tkp, 0, nil, rl); 
        if GetLastError <> ERROR_SUCCESS then 
          Writeln('Error adjusting process privileges.'); 
      end 
      else 
        Writeln('Cannot find privilege value. [' + GetErrorstring + ']'); 
    end; 
    {   if CancelShutdown then 
          if AbortSystemShutdown(nil) = False then 
            Writeln(/'Cannot abort. [/' + GetErrorstring + /']/') 
          else 
           Writeln(/'Cancelled./') 
       else 
       begin 
         if InitiateSystemShutdown(nil, nil, timeDelay, downQuick, Reboot) = False then 
            Writeln(/'Cannot go down. [/' + GetErrorstring + /']/') 
         else 
            Writeln(/'Shutting down!/'); 
       end; 
    } 
  end; 
  //     else begin 
  ExitWindowsEx(flgs, 0); 
  //     end; 
end; 

begin 
  Writeln('Shutdown v0.3 for Win32 (similar to the Linux version)'); 
  Writeln('(c) 2000 NeuralAbyss Software. All Rights Reserved.'); 
  if HasParam('?') or (ParamCount = 0) then 
  begin 
    Writeln('Usage:    shutdown [-akrhfnc] [-t secs]'); 
    Writeln('                  -k:      don''t really shutdown, only warn.'); 
    Writeln('                  -r:      reboot after shutdown.'); 
    Writeln('                  -h:      halt after shutdown.'); 
    Writeln('                  -p:      power off after shutdown'); 
    Writeln('                  -l:      log off only'); 
    Writeln('                  -n:      kill apps that don''t want to die.'); 
    Writeln('                  -c:      cancel a running shutdown.'); 
  end 
  else 
  begin 
    if HasParam('k') then warn := True; 
    if HasParam('r') then reboot := True; 
    if HasParam('h') and reboot then 
    begin 
      Writeln('Error: Cannot specify -r and -h parameters together!'); 
      Exit; 
    end; 
    if HasParam('h') then reboot := False; 
    if HasParam('n') then downQuick := True; 
    if HasParam('c') then cancelShutdown := True; 
    if HasParam('p') then powerOff := True; 
    if HasParam('l') then logoff := True; 
    DoShutdown; 
  end; 
end. 

   
// Parameters for MyExitWindows() 

{EWX_LOGOFF 

Shuts down all processes running in the security context of the process that called the 
ExitWindowsEx function. Then it logs the user off. 

Alle Prozesse des Benutzers werden beendet, danach wird der Benutzer abgemeldet. 

EWX_POWEROFF 

Shuts down the system and turns off the power. 
The system must support the power-off feature. 
Windows NT/2000/XP: 
The calling process must have the SE_SHUTDOWN_NAME privilege. 

F?hrt Windows herunter und setzt den Computer in den StandBy-Modus, 
sofern von der Hardware unterstützt. 

EWX_REBOOT 

Shuts down the system and then restarts the system. 
Windows NT/2000/XP: The calling process must have the SE_SHUTDOWN_NAME privilege. 

F?hrt Windows herunter und startet es neu. 

EWX_SHUTDOWN  

Shuts down the system to a point at which it is safe to turn off the power. 
All file buffers have been flushed to disk, and all running processes have stopped. 
If the system supports the power-off feature, the power is also turned off. 
Windows NT/2000/XP: The calling process must have the SE_SHUTDOWN_NAME privilege. 

F?hrt Windows herunter. 

  
EWX_FORCE  

Forces processes to terminate. When this flag is set, 
the system does not send the WM_QUERYENDSESSION and WM_ENDSESSION messages. 
This can cause the applications to lose data. 
Therefore, you should only use this flag in an emergency. 

Die aktiven Prozesse werden zwangsweise und ohne Rückfrage beendet. 

EWX_FORCEIFHUNG 

Windows 2000/XP: Forces processes to terminate if they do not respond to the 
WM_QUERYENDSESSION or WM_ENDSESSION message. This flag is ignored if EWX_FORCE is used. 

Windows 2000/XP: Die aktiven Prozesse werden aufgefordert, sich selbst zu beenden und 
müssen dies best?tigen. Reagieren sie nicht, werden sie zwangsweise beendet. } 

抱歉!评论已关闭.