现在的位置: 首页 > 综合 > 正文

Linux RHEL 4下安装SNMP并配置

2018年04月01日 ⁄ 综合 ⁄ 共 2148字 ⁄ 字号 评论关闭

--安装-------------
1、先检查有没有安装snmp服务:which snmpd,没有找到就是没有安装

2、再检查一些rpm包有没有安装:
    rpm -qa|grep snmp
        检查是否安装net-snmp-utils-...,net-snmp-libs-...,net-snmp-...三个rpm包
    rpm -qa|grep lm
        检查是否安装lm_sensors-...

3、到网上(http://rpm.pbone.net/)下载或光盘中取上面没有的相关包,并按以下顺序安装:
    rpm -ivh lm_sensors-2.8.7-2.40.3.i386.rpm
    rpm -ivh net-snmp-libs-5.1.2-11.EL4.10.i386.rpm
    rpm -ivh net-snmp-5.1.2-11.EL4.10.i386.rpm
    rpm -ivh net-snmp-utils-5.1.2-11.EL4.10.i386.rpm

4、启动snmp:
    /etc/init.d/snmpd start

5、让开机自动启动此服务:
    chkconfig snmpd on

6、检测服务是否启用:netstat -tanulp | grep snmp

7、验证snmp工具是否可以正常使用:snmptranslate -To | head
    没有报错则说明snmp工具可以正常使用

 

--进行配置(9-13不操作可能也不会影响实际应用)--------------
8、cd /etc/snmp/
    vi snmpd.conf

9、找到
# Make at least  snmpwalk -v 1 localhost -c public system fast again.
#       name           incl/excl     subtree         mask(optional)
view    systemview    included   .1.3.6.1.2.1.1
view    systemview    included   .1.3.6.1.2.1.25.1.1

插入一行,意思是让客户机可以查看.1节点下的所有设备信息,插入后如下:
# Make at least  snmpwalk -v 1 localhost -c public system fast again.
#       name           incl/excl     subtree         mask(optional)
view    systemview    included   .1
view    systemview    included   .1.3.6.1.2.1.1
view    systemview    included   .1.3.6.1.2.1.25.1.1

10、修改Process checks的配置,把下面三个选项注释去掉,去掉后如下:
#  Make sure mountd is running
proc mountd

#  Make sure there are no more than 4 ntalkds running, but 0 is ok too.
proc ntalkd 4

#  Make sure at least one sendmail, but less than or equal to 10 are running.
proc sendmail 10 1

11、修改Executables/scripts配置,找到如下位置:
#exec echotest /bin/echo hello world
把注释去掉

12、修改disk checks配置,找到如下位置:
#disk / 10000
把注释去掉

13、修改load average checks配置,找到如下位置:
#load 12 14 14
把注释去掉

14、设置社区名为public33e9(此名可以随便取,客户端对应即可):
#       sec.name  source          community
com2sec notConfigUser  default       public33e9

15、# Finally, grant the group read-only access to the systemview view.

#       group          context sec.model sec.level prefix read   write  notif
access  notConfigGroup ""      any       noauth    exact  systemview none none

第三行改为:
access  notConfigGroup ""      any       noauth    exact  all none none

16、找到:
##           incl/excl subtree                          mask
#view all    included  .1                               80
去掉第二行的#

17、重启服务:/etc/init.d/snmpd restart

18、最后检测:snmpwalk -v 2c -c public33e9 localhost if
有出现一大片信息,就说明正常了。