现在的位置: 首页 > 综合 > 正文

ORA-600 [2662] Block SCN is ahead of Current SCN [ID 28929.1]

2012年11月29日 ⁄ 综合 ⁄ 共 2734字 ⁄ 字号 评论关闭

 

ORA-600 [2662] "Block SCN is ahead of Current SCN" [ID 28929.1]


 

Modified 09-DEC-2010     Type REFERENCE     Status PUBLISHED

 

 

 

 

Note: For additional ORA-600 related information please read Note:146580.1

 

PURPOSE:           

  This article discusses the internal error "ORA-600 [2662]", what

  it means and possible actions. The information here is only applicable

  to the versions listed and is provided only for guidance.

 

ERROR:             

  ORA-600 [2662] [a] [b] [c] [d] [e]

 

VERSIONS:

  versions 6.0 to 10.1

 

DESCRIPTION:

 

  A data block SCN is ahead of the current SCN.

 

  The ORA-600 [2662] occurs when an SCN is compared to the dependent SCN

  stored in a UGA variable.

 

  If the SCN is less than the dependent SCN then we signal the ORA-600 [2662]

  internal error.

 

ARGUMENTS:

  Arg [a]  Current SCN WRAP

  Arg [b]  Current SCN BASE

  Arg [c]  dependent SCN WRAP

  Arg [d]  dependent SCN BASE

  Arg [e]  Where present this is the DBA where the dependent SCN came from.

 

FUNCTIONALITY:     

  File and IO buffer management for redo logs

 

IMPACT:

  INSTANCE FAILURE

  POSSIBLE PHYSICAL CORRUPTION

 

SUGGESTIONS:       

    

  There are different situations where ORA-600 [2662] can be raised.

 

  It can be raised on startup or duing database operation.

 

  If not using Parallel Server, check that 2 instances have not mounted

  the same database.

 

  Check for SMON traces and have the alert.log and trace files ready

  to send to support.

 

  Check the SCN difference [argument d]-[argument b].

 

  If the SCNs in the error are very close, then try to shutdown and startup

  the instance several times.

 

  In some situations, the SCN increment during startup may permit the

  database to open. Keep track of the number of times you attempted a

  startup.

 

  If the Known Issues section below does not help in terms of identifying

  a solution, please submit the trace files and alert.log to Oracle

  Support Services for further analysis.

 

  Known Issues:

 

  Bug# 5889016   See Note:5889016.8

      Corruption / OERI during recovery

      Fixed:

 

  Bug# 4453449   See Note:4453449.8

      OERI:3020 / corruption errors from multiple FLASHBACK DATABASE

      Fixed: 10.2.0.2, 11.1.0.6

 

  Bug# 2899477   See Note:2899477.8

      Minimise risk of a false OERI[2662]

      Fixed: 9.2.0.5, 10.1.0.2

 

  Bug# 2764106   See Note:2764106.8

      False OERI[2662] possible on SELECT which can crash the instance

      Fixed: 9.2.0.5, 10.1.0.2

 

  Bug# 2216823   See Note:2216823.8

      OERI [2662] reusing a TEMPFILE with a restored database

      Fixed: 10.1.0.2

 

  Bug# 2054025   See Note:2054025.8

      OERI:2662 possible on new TEMPORARY index block

      Fixed: 9.0.1.3, 9.2.0.1

 

  Bug# 851959   See Note:851959.8

      OERI:2662 possible from distributed OPS select

      Fixed: 7.3.4.5

 

  Bug# 647927 P  See Note:647927.8

      Digital Unix ONLY: OERI:2662 could occur under heavy load

      Fixed: 8.0.4.2, 8.0.5.0

 

 

 

 

 

 INTERNAL ONLY SECTION - NOT FOR PUBLICATION OR DISTRIBUTION TO CUSTOMERS

 ========================================================================

 

There were 2 forms of this error until 7.2.3:

 

 Type I:  4/5 argument forms -

                              The SCN found on a block (dependent SCN) is ahead of the

抱歉!评论已关闭.